Ex-Amperometric type TRO(Total Residual Oxidant) sensor - Type : EX-P-HT4, EX-P-STD, EX-P-STD2 and D01 - Ex-proof grade : Ex db ib IIC T5 Gb - Intended for Ballast Water Management System - Manufacturing Location : Halogen Systems Inc. 919 Incline Way, Unit 11, Incline Village, NV 89451, USA
" See Appendix 1 "
|
* Product Specification 1) Product Description ; The EX-P-HT4, EX-P-STD, EX-P-STD2 stands for amperometric Ex-TRO Sensor. All sensor models use an optional display transmitter (Type designation: D01) which provides remote display of all parameters and sensor information. It uses the amperometric method and can be used for continuous monitoring of TRO value of ballast water management system.
2) Nomenclature ========================================================================================= Explosion proof Reference electrode Mounting Remark ========================================================================================= EX -P -HT4 (Hot Tap Long) - ----------------------------------------- -STD (Side Stream) - ----------------------------------------- -STD2 (Extended Flange) - ========================================================================================= 3) Specification ; - Chlorine range : 0 ~ 10.0 ppm as Cl₂ - Chlorine accuracy : ±15% or 0.07 ppm, whichever is greater - Applicable pressure : 0 ~ 10 Bar - Max. flow(velocity) : 5 m/sec - Sample water Temp. : 0 (non-freezing) ~ 40 ℃ - Sample Salinity : 0.2 ~ 38 PSU at 0 ~ 40℃ - Sample pH : 6.5 ~ 8.5 - Rated voltage : 24 VDC at 350mA - Ambient Temp. range : 0 ~ 50 ℃ - IP grade : IP 44 (EX-P-HT4)
* Approved drawings and documents 1) Drawings : EX-P-STD Rev.A, EX-P-HT4 Rev.A, DS-20-000 Rev.0, EX-30-010 Rev.A-11, EX-30-001 Rev.A5, EX-30-010 RED Rev.A11, EX-30-010 STD Rev.A11, EX-31-032 Rev.A4, EX-31-030 Rev.A-06, EX-31-032 Rev.A-03, EX-31-013 Rev.A10, EX-31-013 Rev.A10, EX-31-070 Rev.A5, EX-32-100 STD Rev.A18, EX-32-010 Rev.A6, EX-32-000 Rev.A9, EX-34-000 Rev.A1, EX-35-040 Rev.A11, EX-35-010 Rev.A6, EX-36-001 Rev.A4 2) Manual : Operation and maintenance manual version 4.2.5 Installation Manual EX-38-000 Rev.P 3) Ex Certificate : IECEx LC 18.0010X Issued No.1
* Test Reports, etc. 1) ENV : 14583-1S Rev.0 2) EMC : 14583-1E Rev.3 3) Performance - Evaluating Halogen System's Inc TRO Sensor Using an Adaptation of ISO Method 15839 Rev.1 (Doc. No.: KRTR Rev.1) - Evaluating Halogen System's Inc TRO Sensor Using an Adaptation of ISO Method 15839 Rev.1 (Doc. No.: EXHT-KRTP Rev.4) - Freshwater and Marine Data Supplement to: Evaluating Halogen System's Inc TRO Sensor Using an Adaptation of ISO Method 15839 Rev.4 (Doc. No: EXHT-KRTP Rev.-F&M Data Addition)
* Application / Limitation 1) This approval is granted on the basis of the test reports and the approved documents. 2) Degree of protection shall be complied with Rule Pt.6 Ch.1 Sec.2 201.2.(5). 3) The manufacturer should inform this Society of all kinds of revisions of the equipment including software. If the changes are recognized to affect functionality of the approved equipment, type test to confirm the reliability of the revised equipment may be performed in the presence of our surveyor. 4) Explosion-proof certification by a notified/recognized Certification Body is not covered by this certificate. Ratings and Special Condition for Safe Use in hazardous areas are to be obtained from the relevant valid Ex-Certificate. 5) Ratings and installation requirements for use in hazardous areas are to be obtained from the relevant Ex-Certificate. 6) Unless specially directed by the Administration, this approval is not to be construed as a substitute for a flag Administration's approval. 7) Performance tests were conducted as per EN ISO 15839:2006. Performance characteristics in the laboratory and the field have been determined as per section 5 and 6 of EN ISO 15839:2006. The determined performance characteristics have been compared to product specifications. Performance tests were not conducted under challenge water condition specified in IMO Res. MEPC 300(72) Annex Part 2 and/or 46 CFR 162.060. 8) In case of where the product is used for ballast water management system, the product shall be evaluated to the satisfaction of the Administration, if requested. 9) Operation limitations to grant performance stated in the above "Product Specification"; - Conductivity in water shall be equal to or over than 100 μS/cm at 25℃, at least. - The interference in water quality parameters affecting performance was not verified. - Maintenance and calibration shall be carried out in accordance with Operation and Maintenance Manual version 3.7.
* Individual Product Cert. and Drawing Approval Requirement 1) Individual Product Certification is not required.
* Marking 1) The product or packing is to be marked with the manufacturer's name and type designation on a suitable position.
* Others 1) Test condition (IACS UR E10 Rev.7 basis) ========================================================================================= Test Condition Remark ========================================================================================= EMC All locations excluding the bridge and deck zone - ----------------------------------------------------------------------------------------- Temperature 0 ∼ +55℃ - ----------------------------------------------------------------------------------------- Vibration Acceleration ±0.7g - ----------------------------------------------------------------------------------------- Degree of protection IP44 1) ----------------------------------------------------------------------------------------- * Remark 1) Degree of protection for IP44 has been carried out by EX-P-HT4 ========================================================================================= < End of Certificate >
|